Malvern Panalytical – Particle Characterization, Particle Shape – Morphologi Range

Automated imaging for advanced particle characterization

Morphological imaging is fast becoming an essential technology in the laboratory toolkit for particle characterization. The Morphologi 4 is a fully automated static image analysis system which provides a complete detailed description of the morphological properties of particulate materials. The Morphologi 4-ID combines the same automated static image analysis with Raman spectroscopy in a single, integrated platform, providing component-specific morphological descriptions of chemical species within a blend.

DKSH is the exclusive distributor in Cambodia, Indonesia, Laos, Malaysia, Myanmar, Philippines, Singapore, Taiwan, Thailand and Vietnam.

Inquire Now

Overview

Features

Specifications

Technical Specifications

Morphologi 4-IDMorphologi 4
Measurement type
Particle size
Particle shape
Chemical identification
Contaminant detection and analysis
Particle size range0.5µm – 1300µm0.5µm – 1300µm
Technology
Image analysis
Morphologically Directed Raman Spectroscopy (MDRS)

Available Models

Technical Specifications

TechnologyStatic automated imaging
Particle size parametersCircle equivalent (CE) diameter, length, width, perimeter, area, maximum distance, sphere equivalent (SE) volume, fiber total length, fiber width
Particle shape parametersAspect ratio, circularity, convexity, elongation, high sensitivity (HS) circularity, solidity, fiber elongation, fiber straightness
Particle transparency parametersIntensity mean, intensity standard deviation
Integrated Sample Dispersion UnitFor fully automated dispersion and measurement of dry powders. Manual or SOP control of dispersion pressure, injection time and settling time
Detector18 MP; 4912 x 3684 pixel color CCD array; pixel size 1.25 μm x 1.25 μm
Optical systemNikon CFI 60 brightfield / darkfield system
Dimensions (W, D, H)810 x 520 x 685 mm with carry handles: 1100 x 520 x 685 mm

Rapid, automated particle size and particle shape analysis

Morphologi 4 provides detailed morphological descriptions of particulate samples through static image analysis, enabling a greater understanding of both sample and process.  It can equally be used as an R&D tool to investigate challenging applications and in automated QC analysis where generation of robust, user-independent results and validation are required.

Read more on the website of our partner

Technical Specifications

TechnologyStatic automated imaging
Particle size parametersCircle equivalent (CE) diameter, length, width, perimeter, area, maximum distance, sphere equivalent (SE) volume, fiber total length, fiber width
Particle shape parametersAspect ratio, circularity, convexity, elongation, high sensitivity (HS) circularity, solidity, fiber elongation, fiber straightness
Particle transparency parametersIntensity mean, intensity standard deviation
Integrated Sample Dispersion UnitFor fully automated dispersion and measurement of dry powders. Manual or SOP control of dispersion pressure, injection time and settling time
Detector18 MP; 4912 x 3684 pixel color CCD array; pixel size 1.25 μm x 1.25 μm
Optical systemNikon CFI 60 brightfield / darkfield system
Dimensions (W, D, H)810 x 520 x 685 mm with carry handles: 1100 x 520 x 685 mm

Rapid, automated, component-specific particle characterization in a single, integrated platform

Morphologi 4-ID delivers detailed component-specific morphological descriptions of particulate blends through Morphologically-Directed Raman Spectroscopy (MDRS).  This combines automated particle imaging with Raman spectroscopy in a single, integrated platform, providing the power to unlock complex particle characterization problems.

Read more on the website of our partner

Key Features

  • Automated SOP control for unattended operation and reproducible results, boosting productivity
  • Excellent microscope images, accurate characterization
  • Versatile sample presentation accessories for measuring suspended and filtered samples
  • Advanced manual microscope control mode provides increased value as a shared laboratory resource
  • Rapid automatic particle counting on membrane filters
  • Powerful and intuitive software interface for easy visual and statistical interpretation of data

Morphologi 4-ID in action

Morphologically-Directed Raman Spectroscopy (MDRS) combines automated imaging and chemical identification for advanced particle characterization. This provides rapid, automated component-specific morphological information to help solve your formulation and deformulation challenges, optimize material properties and create confidence throughout development and manufacturing.

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

Key Industries

  • Biopharmaceutical and Biotechnology
  • Electronics
  • Mining & Minerals
  • Pharmaceutical
  • Powders & Pigments / Coating
  • Semiconductor, Solar & Electronics

More Products

Malvern Panalytical

Malvern Panalytical was formed by the merger of Malvern Instruments Limited and PANalytical B.V. on 1st January 2017, has headquarters…

To ensure the download works, please disable your pop-up blocker.
  • Morphologi 4 range factsheet


  • VIETNAM

    DKSH Technology Co.,Ltd
    Head office: 16th Floor, Peakview Tower Building, 36 Hoang Cau Street, O Cho Dua Ward, Dong Da District, Hanoi City.

    Ho Chi Minh Branch: 5th Floor, Viettel Complex Building, 285 Cach Mang Thang Tam, Ward 12, District 10, Ho Chi Minh City.

    Da Nang Branch: 14th Floor, VietinBank Building, 36 Tran Quoc Toan, Hai Chau District, Da Nang city.

    +84 28 3812 5806 Ext 89604

    Contact Now

Delivering Growth – in Asia and Beyond

Follow Us

© DKSH International Ltd.  All Rights Reserved.

test block for Laos

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us